←
Sterghios A. Moschos10,138 posts
Sterghios A. Moschos avatar

Sterghios A. Moschos

@DocMoschos

Founder & CEO PulmoBioMed; FRSC FIBMS Professor @NorthumbriaUni, @docmoschos.bsky.social

◷ Joined September 2011▧ 240 Photos and videos
Sterghios A. Moschos avatar
Sterghios A. Moschos@DocMoschos·6 Sep 2022

100% detection and quantification of SARS-CoV-2 with PBM-HALE, in 1 minute of exhaled breath, requires forced expiration and gives Ct's as low as 25.8. We have updated our preprint with the interim data from our Brazil study 1/n

Post attachment

Our Pre-print on exhaled breath detection of COVID-19 and bacteria from your lung. TL;DR summary: you do not emit any virus if you are infected, have symptoms, and are breathing in a relaxed fashion. This DOES NOT mean COVID-19 isn’t airborne 1/n medrxiv.org/content/10.1101/…

Sterghios A. Moschos avatar
Sterghios A. Moschos@DocMoschos·Apr 29

Cytokine data was also obtained in the second study, but normalisation factors and assay optimisation are required for better interpretation. Correlation work with tidal samples also requires longer sampling 17/x

Sterghios A. Moschos avatar
Sterghios A. Moschos@DocMoschos·Apr 29

Main limitations: these were observational small-sized studies looking at percent positive agreement to nasopharyngeal swab positivity. The n number is small, & false negative rate within each study was not determined. 16/x

Sterghios A. Moschos avatar
Sterghios A. Moschos@DocMoschos·Apr 29

We also found that singing, but not tidal aerosol yield correlated with armspan, a surrogate marker of lung capacity, and BMI. Fatigue on the other hand affected only tidal aerosol yield. Importantly, normalised aerosol viral loads correlated with age. 15/x

Sterghios A. Moschos avatar
Sterghios A. Moschos@DocMoschos·Apr 29

However, 23/24 specimens had higher normalised viral RNA levels in the lower lung compared to the saliva. If any specimen contamination was happening, it was from the lung to the saliva- but drool was collected before breath sampling 14/x

Sterghios A. Moschos avatar
Sterghios A. Moschos@DocMoschos·Apr 29

The normalisation first showed a good correlation to paired salivary viral levels, and no correlation to nasopharyngeal swabs. This worked only for singing specimens (which remained salivary amylase activity-free). 13/x

Sterghios A. Moschos avatar
Sterghios A. Moschos@DocMoschos·Apr 29

Since reactions were setup by volume, not by RNA content (undetectable by UV), we then normalised data to 18S rRNA levels, and compared levels between sample types. This is a standard method in cell biology and was very illuminating 12/x

Sterghios A. Moschos avatar
Sterghios A. Moschos@DocMoschos·Apr 29

11/x The key thing to detectability was the fraction of the total sample processed in the RT-PCR reaction after extraction-purification: as little as 3 min of sample suffices if the entire sample can be loaded onto the RT-PCR. 100% detectability, 73% quantifiable. 11/x

Sterghios A. Moschos avatar
Sterghios A. Moschos@DocMoschos·Apr 29

The last 4 specimens had 18S rRNA Ct values of ~18 (huge amounts), and so did the extraction negative controls- so were also excluded from the analysis. Of the remaining 24, all were positive for viral RNA and 18S rRNA. 10/x

Sterghios A. Moschos avatar
Sterghios A. Moschos@DocMoschos·Apr 29

Of the 30 participants, 2 produced insufficient sample and where excluded. We thinks this had to do with mask fitting. The rest were processed in 3 batches, based on local incidence. 9/x

Sterghios A. Moschos avatar
Sterghios A. Moschos@DocMoschos·Apr 29

The second study was done in a resource limiting primary care centre, compared nasopharyngeal swabs, saliva, tidal breath samples, and singing breath samples. This time we found 18S rRNA and viral RNA in almost all singing aerosols 8/x

Sterghios A. Moschos avatar
Sterghios A. Moschos@DocMoschos·Apr 29

The first cohort we evaluated simply tidally exhaled into the device. We saw no virus RNA in the specimens. However @drkristenkc had shown elevation during singing. So we went back to try again, comparing the two protocols and increasing the sample tested. 7/x

Sterghios A. Moschos avatar
Sterghios A. Moschos@DocMoschos·Apr 29

We next nebulised recombinant viruses, liposomes, virus like particles, polymeric nanoparticles, and invariably showed we can capture these in the device. With these results we justified clinical use for viral pathogen detection. This took place early during the pandemic 6/x

Sterghios A. Moschos avatar
Sterghios A. Moschos@DocMoschos·Apr 29

Computational flow dynamics also backed the experimental data; only the last 48 mL of exhaled breath are efficiently condensed in the device. This ensures enrichment for the aerosols from the bottom of the lung- as backed up by the surfactant protein D data 5/x

Sterghios A. Moschos avatar
Sterghios A. Moschos@DocMoschos·Apr 29

Inflammatory markers were also detectable in the specimen from 10 healthy participants- meaning inflammation can be measured in the lung. These were ~100x lower that surfactant protein D- a marker of the lower respiratory tract epithelial lung fluid 4/x

Sterghios A. Moschos avatar
Sterghios A. Moschos@DocMoschos·Apr 29

2) The fine aerosols with our device are devoid of salivary amylase activity against paired saliva samples. Any saliva would have at least 1>1750 dilution in this specimen. The highly labile 18S rRNA marker was also stable within individuals 3/x