Protest ES Ltd@ProtestESLtd·5m

Coat hooks screwed into the back of a meeting room fire door are easy to miss. 🧥 Two more: - noticeboards fixed through the leaf - bolts added for privacy Each one changes a tested door. 🌐 protestesltd.co.uk?utm_sourc… 📞 01604 696113

Protest ES Ltd avatar
Protest ES Ltd@ProtestESLtd·2h

Cracked glass in a fire door vision panel matters because the glass, beads and glazing seal were all part of what the door was tested with. 🪟 The replacement has to match that evidence too. When did anyone last check yours? 🔍

Post attachment
Protest ES Ltd avatar
Protest ES Ltd@ProtestESLtd·8h

Small redundant screw holes can often be made good with a method the manufacturer allows. A bigger cut-out needs a proper look, and sometimes it's the reason the leaf has to be replaced.

Protest ES Ltd avatar
Protest ES Ltd@ProtestESLtd·8h

Filler, a timber patch or a plate screwed over the hole won't put back what was cut out. The door's fire performance rests on its test evidence, and general-purpose filler isn't part of that.

Protest ES Ltd avatar
Protest ES Ltd@ProtestESLtd·8h

From the corridor it reads as a slightly lumpy patch on the door edge, so it's an easy one to tick off on a walk-round and move on.

Protest ES Ltd avatar
Protest ES Ltd@ProtestESLtd·8h

Somebody swapped the lock on the plant room fire door a while back, and the old cut-out is still there under a smear of wood filler and a coat of paint. 🔩

Protest ES Ltd avatar
Protest ES Ltd@ProtestESLtd·Nov 17

Extinguishers are what we find propping fire doors open most often. 🧯 Close behind: - a bin against the leaf - folded cardboard under the edge - a chair from the next office - a cable tie on the closer protestesltd.co.uk/?utm_sour… 01604 696113

Protest ES Ltd avatar
Protest ES Ltd@ProtestESLtd·Nov 17

Daylight down the middle of a pair of double fire doors, where the leaves should meet, is a defect we'd fix early. 🚪 Usually it's a dropped leaf or worn hinges, and smoke finds that gap first. 🔧 How many of your double doors meet tight?

Post attachment
Protest ES Ltd avatar
Protest ES Ltd@ProtestESLtd·Nov 17

Plastic waste pipe through the riser floor, no collar on it and an open gap all the way round. In a fire that pipe softens and burns away, leaving a hole to the floor above, so it needs a tested collar. protestesltd.co.uk/fire-stop…

Protest ES Ltd avatar
Protest ES Ltd@ProtestESLtd·Nov 17

At the next inspection it gets picked up straight away. Hinges on a fire door have to suit that door's test evidence, usually made to BS EN 1935 for fire door use, with the right screw in every hole and intumescent pads where the door calls for them.

Protest ES Ltd avatar
Protest ES Ltd@ProtestESLtd·Nov 17

It's shinier than the other two and a slightly different size. The door still swings shut, so nobody gave it a second thought.